Abstract:Taking three brands of Ningxia dry red wine as the research object, the content of trans-resveratrol was determined by HPLC with the extraction conditions and chromatographic conditions optimized. The results showed that the detection limit of this method is 0.015 mg/L and the quantitative limit is 0.03 mg/L. Good linearity in the range of 0.03 mg/L-300 mg/L, with the linear equation of y=1.1161x+0.0137 and correlation coefficient of 0.999 6. The reproducibility is good, and the RSD of the standard product is 0.23% and the RSD of the sample is 0.18%. The accuracy is high, and the recovery range is between 92.3%-97.1%. The results showed that the content of trans-resveratrol was closely related to the wine brand and grape variety, and the content of trans-resveratrol in the sample was between 1.97 mg/L-3.70 mg/L.